mirror of
https://github.com/ruvnet/RuView
synced 2026-07-30 18:41:42 +00:00
feat(ruview-gamma): implement ADR-250 Adaptive Gamma Entrainment crate
Governed, deterministic, safety-constrained personalization of 40 Hz-prior light+sound stimulation (RuView sensing + RuVector response modeling + RuFlo audit). 40 Hz is the starting prior, not the hard-coded answer. 11 modules: stimulus/SafetyEnvelope, safety (exclusion screen + latched monitor), response (20-field PersonResponseVector + optional EEG), objective (safe-entrainment score, safety as hard gate), simulator (deterministic ChaCha20 frequency_response_curve), optimizer (calibration sweep + GP/EI + closed-loop), bandit (LinUCB), session (reproducible SHA-256 witness), ruflo (consent/exclusion/envelope/audit/trial-sham/clinician-export/claim-discipline), proof (deterministic bundle witness), math. Safety invariant asserted in tests: no emitted stimulus can ever leave the SafetyEnvelope; non-finite inputs clamp to the conservative floor. Claim discipline: only 'personalized entrainment optimization', never Alzheimer's treatment (ADR-250 §19). Standalone leaf, publish=false pending safety sign-off. Validation: 64 unit/integration + 1 doctest pass; full workspace gate green (2,862 passed, 0 failed); deterministic witness pinned; criterion benches (safety-stop tick ~9.3 ns vs the ADR §17 500 ms bound). Adds ADR-250 doc, registers the crate, updates CLAUDE.md crate table and CHANGELOG. https://claude.ai/code/session_01MjBucx95K4BuUxZi8NWwRH
This commit is contained in:
@@ -0,0 +1,207 @@
|
||||
# ADR-250: Adaptive Gamma Entrainment Using RuVector and RuView
|
||||
|
||||
| Field | Value |
|
||||
|-------|-------|
|
||||
| **Status** | Proposed |
|
||||
| **Date** | 2026-06-09 |
|
||||
| **Owner** | RuView, RuVector, RuFlo clinical systems |
|
||||
| **Decision type** | Architecture, safety, research platform |
|
||||
| **Scope** | Personalized noninvasive sensory stimulation and passive state sensing |
|
||||
| **Codebase target** | `v2/crates/ruview-gamma` (this ADR's reference implementation) |
|
||||
|
||||
> **Not medical advice:** This ADR defines a research and engineering
|
||||
> architecture. It does **not** define an approved Alzheimer's treatment. The
|
||||
> immediate product claim is **personalized entrainment optimization**, never
|
||||
> Alzheimer's treatment.
|
||||
|
||||
---
|
||||
|
||||
## 1. Context
|
||||
|
||||
Recent research suggests that noninvasive 40 Hz multisensory stimulation using
|
||||
light and sound can influence gamma neural activity and may activate glymphatic
|
||||
clearance pathways associated with amyloid removal in Alzheimer's mouse models.
|
||||
The strongest mechanistic support comes from a 2024 Nature paper showing that
|
||||
multisensory gamma stimulation promoted cerebrospinal fluid influx, interstitial
|
||||
fluid efflux, aquaporin-4 polarization, meningeal lymphatic dilation, VIP
|
||||
interneuron signaling, and amyloid clearance in 5XFAD mice. Blocking glymphatic
|
||||
clearance abolished the amyloid-clearing effect.
|
||||
|
||||
Human evidence is promising but still early. A 2022 study in mild probable
|
||||
Alzheimer's disease reported that 40 Hz sensory stimulation was feasible and
|
||||
well tolerated, with exploratory signals around brain structure, connectivity,
|
||||
sleep, and memory. A small 2025 long-term pilot reported daily 40 Hz
|
||||
audiovisual stimulation over two years was safe and feasible and may slow
|
||||
cognitive and biomarker progression, but the sample size was very small and not
|
||||
definitive.
|
||||
|
||||
The field mostly treats 40 Hz as a fixed protocol. That is a useful population
|
||||
prior, but individual brains may differ by baseline gamma state, arousal, sleep
|
||||
quality, sensory acuity, medication, age, disease stage, and comfort tolerance.
|
||||
A 2025 PLOS One study re-evaluated gamma stimulation frequency across 36–44 Hz,
|
||||
supporting the idea that frequency choice should be empirically measured rather
|
||||
than assumed.
|
||||
|
||||
## 2. Problem
|
||||
|
||||
Fixed 40 Hz stimulation creates four engineering limits:
|
||||
|
||||
1. It assumes the same frequency works for everyone.
|
||||
2. It does not continuously verify entrainment.
|
||||
3. It ignores physiological state (sleep, motion, breathing, restlessness, comfort).
|
||||
4. It cannot safely optimize stimulation parameters over time.
|
||||
|
||||
For clinical or wellness-grade deployment, the system must answer: *which
|
||||
frequency, modality, intensity, timing, and session structure produces the
|
||||
strongest safe entrainment for this person in this state?*
|
||||
|
||||
## 3. Decision
|
||||
|
||||
We build an **Adaptive Gamma Entrainment Architecture** where 40 Hz is the
|
||||
initial prior, not the hard-coded answer. The system uses:
|
||||
|
||||
1. **RuView** as the passive state-sensing layer.
|
||||
2. **RuVector** as the personal response-modeling layer.
|
||||
3. A **constrained optimizer** to select stimulation parameters.
|
||||
4. **RuFlo** as the governed workflow, audit, safety, and protocol-execution layer.
|
||||
5. **Clinical-mode separation** to prevent unsupported therapeutic claims.
|
||||
|
||||
The system optimizes stimulation **only within a predefined safety envelope**
|
||||
and separates entrainment optimization from disease-outcome claims.
|
||||
|
||||
## 4. Architecture Overview
|
||||
|
||||
```
|
||||
Person baseline → RuView passive sensing → optional EEG → stimulus session
|
||||
→ response extraction → RuVector personal response vector
|
||||
→ constrained optimizer → next best protocol → RuFlo audit + governance
|
||||
```
|
||||
|
||||
| Component | Role | Output |
|
||||
|-----------|------|--------|
|
||||
| RuView | Passive sensing of body and environment | breathing, motion, posture, stillness, sleep state, adherence |
|
||||
| EEG (optional) | Direct entrainment measurement | gamma power, phase locking, artifact score |
|
||||
| Stimulus controller | Light + sound actuator | frequency, intensity, phase, duty cycle, duration |
|
||||
| RuVector | Learns personal response surface | individual entrainment vector |
|
||||
| Optimizer | Selects next safe stimulation setting | recommended protocol |
|
||||
| RuFlo | Governance and audit | protocol record, safety log, reproducibility trail |
|
||||
|
||||
## 5. Stimulus Search Space
|
||||
|
||||
| Parameter | Default range | Notes |
|
||||
|-----------|---------------|-------|
|
||||
| Frequency | 36–44 Hz | published exploratory range |
|
||||
| Starting prior | 40 Hz | strongest preclinical literature |
|
||||
| Modality | audio, visual, combined | combined preferred (GENUS-style) |
|
||||
| Brightness | bounded low–moderate | avoid unsafe flicker intensity |
|
||||
| Volume | bounded low–moderate | comfort-constrained |
|
||||
| Duty cycle | continuous, ramped, pulsed | start conservative |
|
||||
| Phase | synchronized, offset | explore only after baseline |
|
||||
| Duration | short calibration first | longer only after tolerance |
|
||||
| Time of day | morning, evening, quiet wake | state-dependent |
|
||||
|
||||
## 6. Personal Response Vector
|
||||
|
||||
RuVector represents each person with a compact 20-field adaptive vector
|
||||
(`baseline_gamma, baseline_alpha, alpha_gamma_ratio, gamma_power_gain,
|
||||
phase_locking_value, breathing_rate, breathing_stability, motion_artifact,
|
||||
posture_state, sleep_state, restlessness_score, stimulus_frequency,
|
||||
brightness_level, sound_level, duty_cycle, phase_offset, session_duration,
|
||||
comfort_score, adherence_score, adverse_event_flag`), updated after each
|
||||
session: `R_{t+1} = update(R_t, stimulus_t, response_t, safety_t)`.
|
||||
|
||||
## 7. Optimization Objective
|
||||
|
||||
The optimizer maximizes **safe, stable entrainment**, not raw gamma power:
|
||||
|
||||
```
|
||||
score = w1·gamma_power_gain + w2·phase_locking_gain + w3·breathing_stability
|
||||
+ w4·adherence + w5·comfort
|
||||
− w6·motion_artifact − w7·adverse_event_risk − w8·overstimulation_penalty
|
||||
```
|
||||
|
||||
Default weights: gamma 0.30, phase-locking 0.25, comfort 0.15, breathing 0.10,
|
||||
adherence 0.10, motion penalty 0.05; **safety penalty is a hard constraint, not
|
||||
negotiable**.
|
||||
|
||||
## 8. Learning Method (staged loop)
|
||||
|
||||
- **Phase 1 — Conservative calibration:** short sessions at 36–44 Hz (1 Hz steps).
|
||||
- **Phase 2 — Bayesian optimization:** GP surrogate + Expected Improvement,
|
||||
subject to `safety==true ∧ comfort≥threshold ∧ adverse_event_risk≤threshold`.
|
||||
- **Phase 3 — Contextual bandit:** once enough sessions exist, LinUCB over state
|
||||
context → stimulus action → safe-entrainment reward.
|
||||
- **Phase 4 — Closed-loop control:** mid-session, bounded frequency nudges when
|
||||
entrainment drops, intensity reduction on discomfort, scoring pause on motion
|
||||
spikes, and hard terminate-and-lock on adverse events.
|
||||
|
||||
## 9–12. RuView / RuVector / RuFlo roles & Safety
|
||||
|
||||
RuView supplies non-camera passive context (breathing, motion, posture,
|
||||
stillness, restlessness, sleep proxy, interference, adherence). RuVector
|
||||
supplies adaptive memory (personal vector, session-to-session learning,
|
||||
anonymized nearest-neighbor, drift detection, clustering, recommendation, edge
|
||||
inference) and predicts **safe-entrainment / comfort / artifact / adherence
|
||||
likelihood** — not Alzheimer's improvement. RuFlo governs (consent,
|
||||
inclusion/exclusion, scheduling, safety-stop rules, parameter audit trail, ADR
|
||||
linkage, model-version tracking, clinician export, trial-mode separation).
|
||||
Every session is reproducible via
|
||||
`session_hash = hash(protocol_version, model_version, device_version,
|
||||
stimulus_parameters, sensor_summary, response_summary, safety_events)`.
|
||||
|
||||
**Hard-stop conditions:** headache, dizziness, nausea, agitation, visual
|
||||
discomfort, abnormal distress, seizure-like symptoms, user-stop request, sensor
|
||||
confidence below threshold, protocol outside approved envelope.
|
||||
|
||||
**Exclusion / clinical supervision:** epilepsy or seizure history,
|
||||
photosensitivity, severe migraine sensitivity, severe psychiatric instability,
|
||||
implanted neurological devices, significant sensory impairment affecting
|
||||
protocol validity, medication changes affecting neural response. **The system
|
||||
must never autonomously expand beyond the allowed safety envelope.**
|
||||
|
||||
## 18. Acceptance Criteria
|
||||
|
||||
| Criterion | Target |
|
||||
|-----------|--------|
|
||||
| Frequency control precision | ±0.1 Hz |
|
||||
| Session audit completeness | 100% |
|
||||
| Motion artifact detection | ≥90% valid/invalid classification |
|
||||
| Adaptive protocol improvement | ≥20% entrainment gain vs fixed 40 Hz |
|
||||
| Comfort | no worse than fixed 40 Hz |
|
||||
| Safety stops | 100% logged |
|
||||
| Repeatability | same optimal band within ±1 Hz across 3 sessions |
|
||||
| Claim discipline | no disease-treatment claim in product UI |
|
||||
|
||||
## 19. Non-Goals
|
||||
|
||||
This ADR does **not** claim: RuView treats Alzheimer's; RuVector clears amyloid;
|
||||
RF sensing measures amyloid directly; personalized frequency improves clinical
|
||||
outcomes; consumer deployment is safe without screening; 40 Hz is always optimal.
|
||||
|
||||
## 21. Implementation Roadmap → reference crate `ruview-gamma`
|
||||
|
||||
| Milestone | Module(s) in `ruview-gamma` | Status in this ADR's impl |
|
||||
|-----------|------------------------------|---------------------------|
|
||||
| M1 Simulator | `simulator.rs` (deterministic ChaCha20 response surface) | **Implemented** |
|
||||
| M2 Device harness (contract) | `stimulus.rs`, `safety.rs` (envelope + emergency stop) | **Interfaces + safety implemented** |
|
||||
| M3 RuView integration (contract) | `response.rs` (`RuViewState`) | **State contract implemented** |
|
||||
| M4 EEG validation (contract) | `response.rs` (`EegMeasurement`), `objective.rs` | **Optional input implemented** |
|
||||
| M5 Adaptive optimizer | `optimizer.rs` (Phase 1+2), `bandit.rs` (Phase 3), closed-loop | **Implemented** |
|
||||
| M6 Trial mode | `ruflo.rs` (consent, inclusion/exclusion, sham, audit, session hash) | **Implemented** |
|
||||
|
||||
The crate is a **deterministic, dependency-light leaf** (no internal RuView
|
||||
deps, ChaCha20 PRNG, SHA-256 witness — same discipline as `nvsim`), so the
|
||||
optimizer, safety envelope, and RuVector update logic can be tested and replayed
|
||||
bit-exactly before any hardware or human exposure. Hardware actuation, real RF
|
||||
sensing, and real EEG land behind feature flags / external adapters; this crate
|
||||
implements the governed software core and its proofs.
|
||||
|
||||
## 22. Final Decision Statement
|
||||
|
||||
We build Adaptive Gamma Entrainment as a governed RuView + RuVector
|
||||
architecture. The system treats 40 Hz as the evidence-based starting prior, then
|
||||
learns each person's safe entrainment response curve using passive sensing,
|
||||
optional EEG, constrained optimization, and auditable RuFlo workflows. The
|
||||
immediate product claim is **personalized entrainment optimization** — not
|
||||
Alzheimer's treatment. That distinction keeps the system scientifically
|
||||
credible, clinically safer, and commercially defensible.
|
||||
Reference in New Issue