fix(calibration): close all four ADR-152 behavioral findings pre-hardware-session
The full-loop integration test surfaced three findings; fixing the third exposed a fourth. All four are fixed and regression-guarded: 1. z-band squeeze (enrollment.rs) — anchor motion is now measured from frame-to-frame deltas of the deviation series (|Δz| > Z_DELTA_MOTION 0.5 ∨ |Δφ| > π/6), not from the absolute motion_flagged, which fires at amplitude_z_median > 2.0 vs the EMPTY baseline and so conflated presence strength with motion. A strongly-reflecting still person (z = 3.0 — every frame flagged by the old heuristic) now enrolls. The old unit tests mocked (z=3.0, motion=false), a combination the real deviation() can never emit — which is exactly how the squeeze hid; tests now derive the flag from z the way the producer does. 2. variance-only presence (specialist.rs) — PresenceSpecialist gains a mean-shift channel: present when variance > threshold OR |mean − empty_mean| > mean_dist_threshold (trained at half the empty→occupied mean distance, None when the means don't separate). Detects the motionless person whose body raises the scalar mean but not its variance. Old persisted banks deserialize with the channel inert (serde default None) — variance-only behavior preserved, proven by a fixture test against pre-change JSON. 3. ungated hz embedding (extract.rs) — Features::embedding() zeroes breathing_hz/heart_hz below EMBED_MIN_SCORE (0.25), keeping the random in-band peaks of noise windows out of the posture/anomaly prototype space. Raw fields stay ungated (specialists have their own stricter gates). 4. heart-band lag-floor leakage (extract.rs, found while fixing 3) — a pure 0.30 Hz breathing signal scored 0.67 in the heart band at 3.33 Hz: out-of-band rhythm leaks as a monotonic slope whose max sits at the band's lag floor, so score gating alone cannot stop it. autocorr_dominant now requires the winning lag to be an interior local maximum; band-edge "peaks" are rejected, true in-band peaks (interior by definition) are preserved. full_loop.rs strengthened to drive the fixes end-to-end: the StandStill anchor is now a z=3.0 strong reflector (unenrollable pre-fix), and a new motionless-person runtime case proves mean-channel detection at empty- level variance. Validation: 41 calibration unit + 1 full-loop integration + 23 CLI tests green; cargo test --workspace --no-default-features exit 0. Co-Authored-By: RuFlo <ruv@ruv.net>
This commit is contained in:
@@ -247,7 +247,7 @@ wifi-densepose room-status --room living-room
|
||||
| **P5** | heartbeat + restlessness + anomaly specialists; `runtime.rs` mixture + veto + confidence gating | End-to-end RoomState on hardware; anomaly veto verified | ✅ Done (`runtime.rs`, CLI `room-watch`; breathing read live on COM8 ESP32) |
|
||||
| **P6** | Baseline-drift `STALE` invalidation; SONA online adaptation; optional ADR-105 federation; HF teacher–student distillation | Drift marks bank STALE; AetherArena entry | ◐ Partial (STALE done; SONA/federation/HF-backbone = follow-ups) |
|
||||
|
||||
**Current status (2026-06-10):** Stages 1–5 implemented with *statistical* specialists (threshold/prototype/autocorrelation). 55 tests (35 unit incl. multistatic + 1 full-loop integration + 19 CLI), all passing under qemu-aarch64. **Validation scope is precise:** baseline capture + HTTP API + auth are proven on real CSI (Pi-5 nexmon, 6,813 frames; and an ESP32-S3). The complete `baseline → enroll → train-room → infer` loop is now **proven in-process** on deterministic synthetic CSI (`tests/full_loop.rs`: clean baseline with zero motion flags, 8/8 anchors through the quality gate, 6 specialists trained, JSON bank round-trip, trained-bank inference 18±2 BPM positive / absent negative / foreign-baseline STALE; seed-robust). The one live runtime signal (breathing ~16–31 BPM via `room-watch`) used the *stateless* breathing head, **not** a trained bank; the clean empty-room loop has **not** yet run on-target — the remaining gap is strictly the hardware session (empty room + operator anchors). See the integration doc §7 for three behavioral findings from the full-loop test (z-band squeeze, variance-only presence, ungated hz embedding) worth fixing before that session. SOTA-intake decisions affecting this system (geometry conditioning, checkerboard alignment) are recorded in ADR-152. Open refinements: `--source-format adr018v6` (drive from the Pi's own nexmon), phase-based breathing carrier, RVF/HNSW storage, and the ADR-150 frozen HF backbone the specialists would distill from.
|
||||
**Current status (2026-06-10):** Stages 1–5 implemented with *statistical* specialists (threshold/prototype/autocorrelation). 55 tests (35 unit incl. multistatic + 1 full-loop integration + 19 CLI), all passing under qemu-aarch64. **Validation scope is precise:** baseline capture + HTTP API + auth are proven on real CSI (Pi-5 nexmon, 6,813 frames; and an ESP32-S3). The complete `baseline → enroll → train-room → infer` loop is now **proven in-process** on deterministic synthetic CSI (`tests/full_loop.rs`: clean baseline with zero motion flags, 8/8 anchors through the quality gate, 6 specialists trained, JSON bank round-trip, trained-bank inference 18±2 BPM positive / absent negative / foreign-baseline STALE; seed-robust). The one live runtime signal (breathing ~16–31 BPM via `room-watch`) used the *stateless* breathing head, **not** a trained bank; the clean empty-room loop has **not** yet run on-target — the remaining gap is strictly the hardware session (empty room + operator anchors). The four behavioral findings from the full-loop test (z-band squeeze, variance-only presence, ungated hz embedding, heart-band lag-floor leakage) are FIXED and regression-guarded — see the integration doc §7. SOTA-intake decisions affecting this system (geometry conditioning, checkerboard alignment) are recorded in ADR-152. Open refinements: `--source-format adr018v6` (drive from the Pi's own nexmon), phase-based breathing carrier, RVF/HNSW storage, and the ADR-150 frozen HF backbone the specialists would distill from.
|
||||
|
||||
Validation per CLAUDE.md: `cargo test --workspace --no-default-features` green; hardware verification on the ESP32-S3 (currently COM8) before any release; witness bundle regenerated if the proof surface changes.
|
||||
|
||||
|
||||
@@ -228,7 +228,7 @@ exchange bank/model deltas, never raw CSI. Hardening already in place:
|
||||
The complete `baseline → enroll → train-room → infer` loop is now **proven in-process** on deterministic synthetic CSI (`wifi-densepose-calibration/tests/full_loop.rs` — drives the CLI's exact stage order through the public API, seed-robust across 5 seeds, runs with and without default features). Capture + API + auth are proven on real CSI (both boxes). What remains is strictly the **on-target** run: real CSI, a physically empty room for baseline, and an operator performing the 8 guided anchors — that hardware session is the last open item.
|
||||
|
||||
- **Known follow-ups (appliance backlog):** `--source-format adr018v6` to drive calibration from the Pi's own nexmon (no ESP32/transcoder); the on-target clean-room enroll→train→infer session (above); phase-based (vs mean-amplitude) breathing carrier; RVF/HNSW persistence (currently JSON); enroll/train HTTP endpoints (live `/room/state` already added); ADR-150 Hailo backbone; true 2-node multistatic; ADR-105 federation.
|
||||
- **Behavioral findings from the full-loop test (pre-hardware-session fixes worth considering):** (1) *z-band squeeze*: `BaselineCalibration::deviation` flags motion at `amplitude_z_median > 2.0` while the still-anchor gate needs `presence_z ≥ 1.5` — a strongly-reflecting still person can be rejected as "moving"; presence strength and motion are conflated. Most likely on-hardware enroll failure mode. (2) `PresenceSpecialist` is variance-only — a motionless person raises the scalar *mean* but not variance, so a quiet subject can read "absent" at runtime even though enroll accepted them; adding mean/`presence_z` to the presence decision would close it. (3) `Features::from_series` emits a best-in-band `breathing_hz`/`heart_hz` even at negligible score, injecting random in-band frequencies into the prototype embeddings for noise windows; gating the hz fields on score would tighten posture/anomaly classification.
|
||||
- **Behavioral findings from the full-loop test — all four FIXED pre-hardware-session:** (1) *z-band squeeze* — anchor motion is now measured from frame-to-frame deltas of the deviation series (`|Δz| > 0.5 ∨ |Δφ| > π/6`), not from the absolute `motion_flagged` (which conflated presence strength with motion); a strongly-reflecting still person (z = 3.0, every frame flagged by the old heuristic) now enrolls — regression-guarded in the full-loop test's `StandStill` anchor and `enrollment::tests`. (2) *Variance-only presence* — `PresenceSpecialist` gained a mean-shift channel (|mean − empty mean| vs a trained threshold); a motionless person is detected via the mean even at empty-level variance — regression-guarded in the full-loop motionless-person case; old persisted banks deserialize with the channel inert (variance-only behavior preserved). (3) *Ungated hz embedding* — `Features::embedding()` zeroes `breathing_hz`/`heart_hz` below `EMBED_MIN_SCORE` (0.25), keeping noise-window random frequencies out of the prototype space. (4) *Heart-band leakage* (found while fixing 3): a strong breathing rhythm's autocorrelation leaks into the HR band as a high-score lag-floor edge value (e.g. score 0.67 at 3.33 Hz from a pure 0.30 Hz breath); `autocorr_dominant` now requires the winning lag to be an interior local maximum, rejecting band-edge leakage while preserving true in-band peaks.
|
||||
|
||||
**Reference:** ADR-151 (`docs/adr/ADR-151-room-calibration-specialist-training.md`), ADR-135 (baseline),
|
||||
ADR-029 (multistatic), ADR-150 (RF Foundation Encoder), ADR-105 (federation), ADR-147 (OccWorld/Hailo).
|
||||
|
||||