groups: # Log event names for the sensing server's curated telemetry — each # instrumented `tracing` call site carries one of these as its explicit # event name (never tracing's default `event :`), so the # exported Logs signal stays registry-backed. Uncurated log lines keep # their default names; only these events are part of the contract. - id: event.ruview.node.online type: event name: ruview.node.online stability: development brief: > A sensing node delivered its first frame (CSI or edge-vitals) — either a new node joining the mesh or a previously evicted node returning. attributes: - ref: ruview.node.id requirement_level: required - id: event.ruview.node.offline type: event name: ruview.node.offline stability: development brief: > A sensing node was evicted after delivering no frames for the staleness window (60 s). attributes: - ref: ruview.node.id requirement_level: required - id: event.ruview.csi.stats type: event name: ruview.csi.stats stability: development brief: > Periodic CSI capture snapshot (every 100 sensing ticks): total frames processed and currently active nodes. attributes: - ref: ruview.csi.frames_total requirement_level: required - ref: ruview.csi.nodes_active requirement_level: required - ref: ruview.csi.source requirement_level: recommended - id: event.ruview.presence.changed type: event name: ruview.presence.changed stability: development brief: > The smoothed presence classification flipped between present and absent. Emitted on transitions only, never per frame. attributes: - ref: ruview.presence.state requirement_level: required - ref: ruview.motion.level requirement_level: recommended - ref: ruview.inference.confidence requirement_level: recommended - ref: ruview.persons.count requirement_level: recommended - ref: ruview.csi.source requirement_level: recommended - id: event.ruview.vitals.estimate type: event name: ruview.vitals.estimate stability: development brief: > Periodic vital-sign estimate (breathing / heart rate with confidences), emitted on the ruview.csi.stats cadence when the detector produced an estimate. attributes: - ref: ruview.vitals.breathing_rate_bpm requirement_level: recommended - ref: ruview.vitals.heart_rate_bpm requirement_level: recommended - ref: ruview.vitals.breathing_confidence requirement_level: recommended - ref: ruview.vitals.heartbeat_confidence requirement_level: recommended - ref: ruview.csi.source requirement_level: recommended - id: event.ruview.fall.detected type: event name: ruview.fall.detected stability: development brief: > An ESP32 edge-vitals frame raised its fall flag. Edge-triggered on the flag's rising edge per node, not re-emitted while it stays set. attributes: - ref: ruview.node.id requirement_level: required - id: event.ruview.mqtt.error type: event name: ruview.mqtt.error stability: development brief: > An MQTT publish or connection error in the Home Assistant discovery publisher; the publisher reconnects and retries. attributes: - ref: ruview.node.id requirement_level: opt_in - id: event.ruview.model.loaded type: event name: ruview.model.loaded stability: development brief: An inference model was loaded via the model-management API. attributes: - ref: ruview.model.id requirement_level: required