Files
ruvnet--RuView/docs
ruv 0043613c6d test(calibration): full-loop integration test — baseline→enroll→train→infer proven in-process (ADR-151 §7 gap, software half)
Closes the software half of PR #989's headline validation gap: the
complete calibration loop had never run end-to-end anywhere, even
in-process. tests/full_loop.rs (412 lines, deterministic xorshift32
room simulator, HT20/52-subcarrier/20Hz, same fingerprint family as
the ADR-135 roundtrip test) now drives the CLI's exact stage order
through the public API:

  1. baseline  — 600 static frames, zero motion flags post-warmup,
                 calibration_uuid() exactly as the CLI derives it
  2. enroll    — all 8 AnchorLabel::SEQUENCE anchors through
                 AnchorQualityGate::default(), session is_complete()
  3. extract   — AnchorFeature::from_series recovers injected 0.25Hz
                 and 0.125Hz breathing within ±0.04Hz
  4. train     — SpecialistBank::train fits all 6 specialists; JSON
                 round-trip and the runtime consumes the RELOADED bank
  5. infer     — positive: never-enrolled 0.30Hz subject reads present,
                 18±2 BPM; negative: empty window reads absent;
                 degradation: foreign baseline_id flags STALE

Seed-robust (5 seeds), passes with and without default features:
36 unit + 1 integration green.

Validation docs updated (ADR-151 §7 + integration doc §7 matrix): what
remains is strictly the on-target hardware session (real CSI, physically
empty room, operator performing the guided anchors). Three behavioral
findings from building the test are recorded for pre-session triage:
z-band squeeze between baseline motion flagging (z>2.0) and the still-
anchor gate (presence_z≥1.5) — likeliest on-hardware enroll failure;
variance-only PresenceSpecialist missing motionless-person mean shift;
ungated breathing_hz/heart_hz in noise-window embeddings.

Co-Authored-By: RuFlo <ruv@ruv.net>
2026-06-10 14:50:55 -04:00
..