After 3 systematic hypotheses tested + rejected (radio coex, OpenThread shadowing, manual RX re-arm), the 802.15.4 leader-election bug is narrowed to: TX path works perfectly (~10/s clean, 0 fail), but the RX path stops after exactly 1 frame. Manual esp_ieee802154_receive() from either callback bootloops the driver (verified across all 3 boards). The IDF reference example uses the same handle_done-only pattern as this code, implying the driver should auto-restart RX — but empirically doesn't here. Either a half-duplex radio state issue or an IDF v5.4 bug. Tracked as known issue D1 in WITNESS-LOG-110. Changes shipped: - c6_twt.c: ESP_ERR_INVALID_ARG added to graceful-fallback list (empirically: ruv.net AP advertises TWT Responder=0, IDF driver validates against AP HE capability and rejects with INVALID_ARG) - c6_timesync.c: diagnostic counters (s_tx_count, s_tx_fail, s_rx_count, s_rx_magic_match) + per-10-beacon log line preserved so future investigation has the diagnostic harness ready - sdkconfig.defaults.esp32c6: 15.4 channel default 15 → 26 (non-overlap with WiFi 2.4 GHz channels), OpenThread disabled (we use raw 15.4) - promiscuous=true on the radio (broadcast frames addressed to 0xFFFF) - WITNESS-LOG-110 §D1 expanded with the full diagnostic trace + 3-hypothesis investigation record Cross-node sync claim (B3) BLOCKED until either an IDF maintainer trace or a working multi-board reference is available. The other three SOTA dimensions (HE-LTF, TWT cadence, 5 µA hibernation) are also still unverified and need different hardware (11ax AP, INA meter) — honestly recorded in §B. Tracking: ruvnet/RuView#762, task #30 closed as known-issue. Co-Authored-By: claude-flow <ruv@ruv.net>