Lands the remaining six §3.12 v1 primitives: - `distress` (PossibleDistress) — EWMA baseline HR + 1.5× multiplier + agitated motion + no-fall + 60 s dwell → ON. Refractory 5 min after exit. Baseline only updates when NOT active AND NOT in candidate-distress state (low motion, HR near baseline) so a sustained elevated HR doesn't drift the baseline up before the dwell completes — without this guard the test would never fire. - `elderly_anomaly` (ElderlyInactivityAnomaly) — current idle stretch > 2× longest-observed-idle baseline. Baseline floor at 30 min so the first day doesn't fire spuriously. 24 h refractory per resident. - `meeting` (MeetingInProgress) — n_persons ≥ 2 + low-amplitude motion (1–20%) + 10 min dwell → ON. 2 min exit dwell on count drop. - `fall_risk` (FallRiskElevated) — 0–100 continuous score from near-fall count in trailing 24 h + recent motion variance. Emits Scalar every tick; emits Event on upward threshold crossing (default 70). - `bed_exit` (BedExit) — edge-triggered event: was in bed_zone, now not, between 22:00 and 06:00 local (wrap-around window honoured). - `multi_room` (MultiRoomTransition) — edge-triggered event: zone exit + different zone enter within 10 s gap. Reason payload carries from/to zone tags so HA automations can route paths. Bus wired to dispatch all 10 primitives; `SemanticKind` enum expanded to match. `tick()` returns up to 10 events per snapshot. 32 new tests (66 semantic + 45 mqtt + 6 cli = **117 total**): - distress (7): does-not-fire-with-normal-HR, fires-on-sustained- elevated-HR-with-motion, does-not-fire-during-fall, exits-when- motion-calms-and-HR-normalises, refractory-blocks-immediate-refire, refire-allowed-after-refractory, baseline-does-not-track-during- active. - elderly_anomaly (5): fires-when-idle-exceeds-2x-baseline, does-not- fire-before-threshold, motion-clears-active-state, baseline-grows- to-observed-max, refractory-prevents-repeat-alerts. - meeting (4): fires-after-dwell-with-2+, does-not-fire-with-1- person, does-not-fire-with-high-motion, exits-after-2-min-of-low- count. - fall_risk (5): warmup-blocks, emits-scalar-when-active, score- grows-with-falls, emits-event-when-crossing-threshold, fall- history-evicts-after-24h. - bed_exit (6): fires-on-bed-to-non-bed-overnight, does-not-fire- during-day, does-not-fire-without-prior-in-bed, warmup-blocks, does-not-fire-when-bed-zones-unconfigured, fires-just-after- midnight-window-start. - multi_room (5): fires-when-zone-changes-quickly, does-not-fire- after-long-gap, does-not-fire-on-same-zone-re-entry, warmup-blocks, handles-simultaneous-zone-swap. ADR-115 §3.12 inference layer now complete. Each primitive has warmup, hysteresis, explainability tags, configurable thresholds. Adding a v2 primitive is one file + one bus entry. Refs #776. Co-Authored-By: claude-flow <ruv@ruv.net>