Files
ruvnet--RuView/v2/.claude-flow/daemon-state.json
T
rUv f49c722764 chore(repo): rename rust-port/wifi-densepose-rs → v2/ (flatten to one level) (#427)
The Rust port lived two directories deep (rust-port/wifi-densepose-rs/)
without any sibling under rust-port/ that warranted the extra level.
Move the whole workspace up to v2/ to match v1/ (Python) at the same
depth and shorten every cd / build command across the repo.

git mv preserves history for all tracked files. 60 files updated for
path references (CI workflows, ADRs, docs, scripts, READMEs, internal
.claude-flow state). Two manual fixes for relative-cd paths in
CLAUDE.md and ADR-043 that became wrong after the depth change
(cd ../.. → cd ..).

Validated:
- cargo check --workspace --no-default-features → clean (after target/
  nuke; the gitignored target/ was carried by the OS rename and had
  hard-coded old paths in build scripts)
- cargo test --workspace --no-default-features → 1,539 passed, 0 failed,
  8 ignored (same totals as pre-rename)
- ESP32-S3 on COM7 → still streaming live CSI (cb #40300, RSSI -64 dBm)

After-merge follow-up: contributors should `rm -rf v2/target` once and
let cargo regenerate from the new path.
2026-04-25 21:28:13 -04:00

135 lines
3.3 KiB
JSON

{
"running": true,
"startedAt": "2026-02-28T14:10:51.128Z",
"workers": {
"map": {
"runCount": 5,
"successCount": 5,
"failureCount": 0,
"averageDurationMs": 1.6,
"lastRun": "2026-02-28T14:40:51.152Z",
"nextRun": "2026-02-28T14:40:51.149Z",
"isRunning": false
},
"audit": {
"runCount": 3,
"successCount": 0,
"failureCount": 3,
"averageDurationMs": 0,
"lastRun": "2026-02-28T14:32:51.145Z",
"nextRun": "2026-02-28T14:42:51.146Z",
"isRunning": false
},
"optimize": {
"runCount": 2,
"successCount": 0,
"failureCount": 2,
"averageDurationMs": 0,
"lastRun": "2026-02-28T14:39:51.146Z",
"nextRun": "2026-02-28T14:54:51.146Z",
"isRunning": false
},
"consolidate": {
"runCount": 2,
"successCount": 2,
"failureCount": 0,
"averageDurationMs": 1,
"lastRun": "2026-02-28T14:17:51.145Z",
"nextRun": "2026-02-28T14:46:51.133Z",
"isRunning": false
},
"testgaps": {
"runCount": 1,
"successCount": 0,
"failureCount": 1,
"averageDurationMs": 0,
"lastRun": "2026-02-28T14:23:51.138Z",
"nextRun": "2026-02-28T14:43:51.138Z",
"isRunning": false
},
"predict": {
"runCount": 0,
"successCount": 0,
"failureCount": 0,
"averageDurationMs": 0,
"isRunning": false
},
"document": {
"runCount": 0,
"successCount": 0,
"failureCount": 0,
"averageDurationMs": 0,
"isRunning": false
}
},
"config": {
"autoStart": false,
"logDir": "/home/user/wifi-densepose/v2/.claude-flow/logs",
"stateFile": "/home/user/wifi-densepose/v2/.claude-flow/daemon-state.json",
"maxConcurrent": 2,
"workerTimeoutMs": 300000,
"resourceThresholds": {
"maxCpuLoad": 2,
"minFreeMemoryPercent": 20
},
"workers": [
{
"type": "map",
"intervalMs": 900000,
"offsetMs": 0,
"priority": "normal",
"description": "Codebase mapping",
"enabled": true
},
{
"type": "audit",
"intervalMs": 600000,
"offsetMs": 120000,
"priority": "critical",
"description": "Security analysis",
"enabled": true
},
{
"type": "optimize",
"intervalMs": 900000,
"offsetMs": 240000,
"priority": "high",
"description": "Performance optimization",
"enabled": true
},
{
"type": "consolidate",
"intervalMs": 1800000,
"offsetMs": 360000,
"priority": "low",
"description": "Memory consolidation",
"enabled": true
},
{
"type": "testgaps",
"intervalMs": 1200000,
"offsetMs": 480000,
"priority": "normal",
"description": "Test coverage analysis",
"enabled": true
},
{
"type": "predict",
"intervalMs": 600000,
"offsetMs": 0,
"priority": "low",
"description": "Predictive preloading",
"enabled": false
},
{
"type": "document",
"intervalMs": 3600000,
"offsetMs": 0,
"priority": "low",
"description": "Auto-documentation",
"enabled": false
}
]
},
"savedAt": "2026-02-28T14:40:51.152Z"
}