Files
ruvnet--RuView/v2/crates/ruview-gamma/README.md
T
Claude 46b4d63dad feat(ruview-gamma): centralize claim-gate invariant + add HIL acceptance contract
Two of the "what to optimize next" items, as enforced code:

1. Hard claim gate: extract the release rule into a single
   acceptance::claim_allowed(entrainment, safety, adherence, repeatability)
   = strict AND of all four, used by every path. A test proves every 3-of-4
   subset is denied, so no path can silently weaken the gate to an OR/subset.

2. Hardware-in-the-loop contract (new hil module): verify_hil grades a
   captured actuator bench measurement against fixed targets — LED frequency
   +/-0.1 Hz, audio-visual sync < 5 ms, stop-signal -> actuator-off < 100 ms,
   session-hash reproducibility 100%, EEG entrainment lift >= 20% over fixed
   40 Hz. Every failure mode fails closed (missing/NaN stop measurement, no
   replay, any hash mismatch). The crate stays a deterministic leaf: firmware
   records the measurements, this module grades them.

README: benchmark table (safety tick ~8 ns, recommend ~15 us, cohort kNN/500
~15 us, calibration ~115 us, acceptance grading ~425 us enrollment-only) and
the positioning line — "a governed personalization engine that refuses to
overpromise."

9 new tests; crate now 97 + 1 doctest; pinned witness 13cb164c... preserved.
Workspace gate: 2,898 passed / 0 failed.

https://claude.ai/code/session_01MjBucx95K4BuUxZi8NWwRH
2026-06-10 04:31:28 +00:00

216 lines
11 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# ruview-gamma — Adaptive Sensory Neuromodulation (ADR-250)
> **The most valuable thing here is not 40 Hz. It is a governed personalization
> engine that refuses to overpromise.**
The control brain for an adaptive light-and-sound neuromodulation device. The
device plays stimulation; **RuView** reads the body as feedback; **RuVector**
learns the personal response map; **RuFlo** governs the safety, audit trail, and
claim boundary. The breakthrough is not speed alone — it is **safe adaptive
personalization with proof discipline**.
It starts from 40 Hz as the research prior, then learns whether a person
responds better at 38.5, 40, 41.2, or another safe setting — watching breathing,
stillness, restlessness, adherence, and sensor confidence. If something goes
wrong, the session locks. If a program has not proven entrainment, safety,
adherence, and repeatability, it cannot advertise a benefit — it returns
*research use only*.
## Benchmarks (this container — indicative)
| Path | Current | Role |
|------|---------|------|
| Safety tick | ~8 ns | real-time stop path |
| Recommendation | ~15 µs | per-session decision |
| Cohort kNN (500 profiles) | ~15 µs | warm-start matching |
| Calibration sweep | ~115 µs | setup and tuning |
| Full acceptance grading | ~425 µs | enrollment-only (offline) |
The per-session control loop is microseconds; the heavier acceptance grading is
enrollment-time work, not on the loop. No regression across the optimization
passes.
## The hard claim gate
A program's benefit claim is releasable through exactly one invariant
(`acceptance::claim_allowed`), used everywhere:
```text
claim_allowed = entrainment_pass AND safety_pass
AND adherence_pass AND repeatability_pass
```
Anything short of all four returns `research use only — … no claim`
(`acceptance::NO_CLAIM`). The marketing claim is unreadable except through the
gate.
## Next milestone — hardware in the loop (`hil`)
The software core is proven against a deterministic simulator; the next
acceptance bar is a real LED + speaker actuator (e.g. ESP32-driven) plus the
stop path. `hil::verify_hil` grades a captured bench measurement against fixed
targets:
| Test | Target |
|------|--------|
| LED frequency accuracy | ±0.1 Hz |
| Audio-visual sync drift | < 5 ms |
| Stop signal → actuator off | < 100 ms |
| Session-hash reproducibility | 100% |
| EEG entrainment lift vs fixed 40 Hz | ≥ 20% |
---
Governed, deterministic, **safety-constrained** personalization of 40 Hz-prior
multisensory (light + sound) stimulation. Treats 40 Hz as the evidence-based
*starting prior*, then learns each person's safe entrainment response curve using
passive RuView sensing, optional EEG, a constrained optimizer, and auditable
RuFlo workflows.
> **Not medical advice / not a medical device.** This crate is a research and
> engineering platform. The only claim it makes is **"personalized entrainment
> optimization"** (`ruview_gamma::PRODUCT_CLAIM`) — never Alzheimer's treatment,
> amyloid clearance, or any clinical outcome (ADR-250 §19). It performs **no
> hardware actuation**: real stimulus delivery, RF sensing, and EEG arrive
> through external adapters behind feature flags after this governed software
> core ships (ADR-250 §21, Milestones 24).
## Why it exists
The field mostly treats 40 Hz as a fixed protocol. But individual brains differ
by baseline gamma, arousal, sleep, sensory acuity, medication, age, and comfort
(the 2025 PLOS One 3644 Hz re-evaluation). Fixed 40 Hz (1) assumes one
frequency fits all, (2) never verifies entrainment, (3) ignores physiological
state, and (4) cannot safely optimize over time. This crate closes that loop.
## The safety invariant
**No recommendation, calibration step, bandit arm, or closed-loop nudge can ever
emit a `StimulusParameters` outside the `SafetyEnvelope`.** Every emitting path
clamps to the envelope and is asserted against `SafetyEnvelope::contains` in
tests. The optimizer never widens the envelope — only an operator constructs a
wider one deliberately (ADR-250 §12). Non-finite (NaN/∞) inputs clamp toward the
conservative floor, never the cap.
## Module map
| Module | Role (ADR-250 §) | Highlights |
|--------|------------------|------------|
| `stimulus` | §5, §12 | `StimulusParameters`, `SafetyEnvelope` (validate / clamp / grids) |
| `safety` | §12 | exclusion screen, latched `SafetyMonitor`, hard-stop reasons |
| `response` | §6, §9, §10 | `RuViewState`, optional `EegMeasurement`, 20-field `PersonResponseVector` (RuVector memory) with sticky adverse flag |
| `objective` | §7 | safe-entrainment score; safety is a hard gate, not a weight; RF-only proxy when EEG absent |
| `simulator` | §21 M1 | deterministic ChaCha20 `frequency_response_curve(person, state, stimulus)` |
| `optimizer` | §8 | Phase-1 calibration sweep, Phase-2 GP + Expected-Improvement, Phase-4 closed-loop control |
| `bandit` | §8 P3 | LinUCB contextual bandit over envelope-safe arms |
| `ruvector` | §10 items 36 | anonymized `ProfileStore` (one-way hashed tags), deterministic kNN, cohort warm-start priors (down-weighted pseudo-observations), `DriftDetector` over the physiological sub-vector, deterministic k-means clustering |
| `program` | §23 | `NeuroProgram` catalog (7 use cases) — per-program envelope, prior, objective, state-gating, evidence level, and gated claim |
| `acceptance` | §18/§23.1 | `AcceptanceHarness` + `ClaimGate` + the `claim_allowed` invariant — entrainment/safety/adherence/repeatability gate; a program's claim is unreadable until all four pass |
| `hil` | §17/§21 M2 | hardware-in-the-loop contract: `verify_hil` grades a captured actuator measurement (LED ±0.1 Hz, A/V sync < 5 ms, stop < 100 ms, hash 100%, EEG lift ≥ 20%) |
| `session` | §11, §13 | hashable `SessionRecord`, reproducible `session_hash` (SHA-256, quantized canonical form) |
| `ruflo` | §11 | consent → exclusion → envelope → run → monitor → score → update → witnessed audit; trial/sham mode; clinician export; claim discipline |
| `proof` | — | deterministic bundle witness (mirrors `nvsim` / `verify.py`) |
| `math` | — | dependency-light numerics (erf, normal CDF/PDF, Cholesky, RBF) |
## Quick start
```rust
use ruview_gamma::{
ruflo::{Consent, RufloGovernor},
response::RuViewState,
simulator::{LatentPerson, ResponseSimulator},
stimulus::{SafetyEnvelope, StimulusParameters},
};
let envelope = SafetyEnvelope::conservative();
let mut gov = RufloGovernor::enroll("subject-001", envelope, &[], Consent::Granted)
.expect("cleared to participate");
// Milestone 1: drive the governed loop with the deterministic simulator.
let sim = ResponseSimulator::new(42);
let latent = LatentPerson::from_id("subject-001");
let state = RuViewState::calm_baseline();
gov.run_calibration(&sim, &latent, &state, 5.0, 0).unwrap();
let rec = gov.recommend(&StimulusParameters::prior());
assert!(envelope.contains(&rec.stimulus)); // always inside the envelope
```
## Test / validate / benchmark
```bash
cargo test -p ruview-gamma --no-default-features # 64 unit/integration + 1 doctest
cargo bench -p ruview-gamma --no-default-features # criterion micro-benchmarks
```
Determinism is proven, not assumed: `proof::Proof::reference_witness()` runs a
fixed reference participant through the full governed pipeline and pins the
bundle SHA-256 (`Proof::EXPECTED_WITNESS`); the test fails on any silent drift in
the optimizer, simulator, response update, or session hashing.
### Measured (this container, indicative — not a regression gate)
| Bench | Median | Note |
|-------|--------|------|
| `gamma_safety_tick` | ~9.3 ns | vs ADR-250 §17 < 500 ms hard-stop latency bound |
| `gamma_bandit_select` | ~74 ns | LinUCB decision |
| `gamma_bayesian_recommend` | ~19 µs | GP + EI over the 0.1 Hz envelope grid (was ~105 µs: the GP is now factorized once per recommend, not once per grid candidate — 81%, bit-identical) |
| `gamma_calibration_sweep` | ~135 µs | full 9-session enroll → simulate → score → update → witness (was ~486 µs, 71%) |
| `gamma_cohort_knn_500` | ~15 µs | exact kNN over 500 anonymized profiles |
| `gamma_cohort_warm_start_500` | ~16 µs | full cohort prior construction (runs once per enrollment) |
| `gamma_acceptance_grade_program` | ~425 µs | full 3-repeat program acceptance grading (offline gate) |
## Adaptive sensory neuromodulation platform (ADR-250 §23)
40 Hz is one prior in one program — the engine is a general personal
neural-rhythm optimization platform. `NeuroProgram::catalog()` ships seven use
cases (Alzheimer's research, post-stroke cognition, sleep optimization,
attention/working-memory, mood/arousal, home wellness, drug+device trial
infrastructure), each with its **own** safety envelope, prior, objective
weighting, physiological-state gating (the sleep program permits `Asleep` and
caps brightness near-dark; attention requires wakefulness), evidence level, and
a single non-disease claim. `RufloGovernor::enroll_program` wires it all in;
`enroll` stays the bare Alzheimer's-defaults path (so the pinned witness holds).
**Claim discipline is executable.** A program's claim can only be read through
the acceptance gate:
```rust
use ruview_gamma::acceptance::{AcceptanceHarness, AcceptanceCriteria};
use ruview_gamma::program::NeuroProgram;
# use ruview_gamma::simulator::LatentPerson;
# use ruview_gamma::response::RuViewState;
let harness = AcceptanceHarness::new(42, AcceptanceCriteria::default());
let report = harness.evaluate(
&NeuroProgram::sleep_optimization(),
&LatentPerson::from_id("subject"),
&RuViewState::calm_baseline(),
);
// Returns the program claim ONLY if entrainment + safety + adherence +
// repeatability all pass; otherwise the research-only NO_CLAIM string.
let _claim = report.claim_gate().claim();
```
## Self-learning across people (ADR-250 §10)
`RufloGovernor::export_anonymized_profile()` publishes a participant's 20-field
vector + per-frequency scores from **safe sessions only** under a one-way hashed
tag; `seed_from_cohort(&store, k)` warm-starts a new person's optimizer from the
k nearest responders as **down-weighted pseudo-observations**
(`observe_prior`, ≥25× the real-observation noise). Priors shape where the
optimizer looks first but never count as measured data — they are excluded from
the EI incumbent, the audit log, and the clinician report. Per-session
`drift_status()` (Welford centroid over the *physiological* sub-vector —
stimulus inputs masked out) flags when recalibration is warranted.
## Roadmap (ADR-250 §21)
M1 simulator ✅ · M2 device harness (envelope + e-stop contract) ✅ · M3 RuView
state contract ✅ · M4 optional EEG input ✅ · M5 adaptive optimizer (BO + bandit
+ closed-loop) ✅ · M6 trial mode (sham/blinding + clinician export) ✅ ·
§10 RuVector self-learning (cohort warm-start, drift detection, clustering) ✅.
Hardware actuation, real RF sensing, and real EEG land behind feature-flagged
adapters. An HNSW backend (the `ruvector` crates) drops in for `ProfileStore`
once cohorts grow past ~10⁵ profiles.