ADR-293: Vitals ground-truth rig — reference ingest, time alignment, and agreement metrics
- Status: Accepted — initial implementation (this PR)
- Date: 2026-08-10
- Deciders: ruv
- Tags: vitals, validation, ground-truth, bland-altman, evidence, honesty
Context
wifi-densepose-vitals (ADR-021) extracts breathing (0.1–0.5 Hz) and heart
rate (0.8–2.0 Hz) from CSI. The 2026 research sweep found that every credible
vitals result in the literature ships with reference-sensor ground truth
(chest strap, pulse oximeter, ECG, or PSG), and that WiFi heart-rate numbers
without stated scope (single person, static, line-of-sight, short range) are
systematically misleading. RuView currently has no way to produce a MEASURED
vitals number: there is no reference-signal ingest, no time alignment between
CSI-derived estimates and a reference device, and no agreement statistics.
CLAUDE.md requires accuracy statements to be tagged MEASURED (with a reproducer), CLAIMED, or SYNTHETIC. For vitals, MEASURED is currently unreachable.
Options considered
- Live BLE/ANT+ integration with reference devices. Rejected for now: drivers and pairing are a hardware/product concern; the blocking gap is the evaluation math, not the radio link.
- File-based reference ingest + offline agreement analysis. Chosen: every consumer reference device (Polar, Garmin, oximeters) exports timestamped series; a file boundary keeps the crate dependency-free and the pipeline deterministic.
Decision
Add a groundtruth module to v2/crates/wifi-densepose-vitals:
1. Reference series ingest
ReferenceSeries: timestamped samples (unix millis + value) for one measurand (HeartRateBpmorBreathingRateBrpm), with device metadata (make/model, measurement principle). Parsed from CSV (timestamp_ms,valuewith a header line); malformed rows are rejected with row-numbered errors — untrusted file input validated at the boundary. Non-monotonic timestamps are an error, not silently sorted.
2. Time alignment
- Constant-offset estimation by maximizing normalized cross-correlation of the estimate series against the reference over a bounded lag window (default ±30 s), on a common resampled grid (nearest-sample, no interpolation of physiological values across gaps larger than a configurable limit).
- Optional linear clock-drift fit (offset + rate) for long sessions. Alignment parameters are reported, never silently applied.
3. Agreement metrics
AgreementReport: n paired samples, coverage fraction (time where both series had valid samples), MAE, RMSE, mean error (bias), Bland–Altman 95% limits of agreement, and percentage-within-tolerance (configurable, default ±2 bpm HR / ±1 brpm breathing).- Session scope is mandatory metadata: subject count, motion state (static/moving), line-of-sight (LOS/NLOS/through-wall), distance band. A report without scope cannot be constructed.
4. Evidence tagging
EvidenceGrade::Measuredis only constructible when the report carries a reference device, non-zero paired samples, minimum coverage, and a reproducer command string; otherwise the report grades asClaimed(real data, no reference) orSynthetic(generated input). This mirrors ADR-291's enforcement-in-types approach and the CLAUDE.md tagging rule.
Consequences
- RuView can convert vitals claims from CLAIMED to MEASURED with a reproducible offline analysis, session by session, scope by scope.
- Honest reporting will likely show heart-rate performance below marketing intuition, especially NLOS/moving — that is the purpose.
- CSV ingest means a manual export step per session; acceptable at current scale, and the format is the de-facto export of consumer reference gear.
- No clinical claim is implied: agreement statistics against consumer reference devices are engineering evidence, not medical validation.
Validation
cargo test -p wifi-densepose-vitals— CSV rejection cases, alignment recovery of known synthetic offsets/drifts, agreement metrics against hand-computed fixtures, evidence-grade constructibility rules.cargo bench -p wifi-densepose-vitals— criterion benchmark for alignment over hour-scale synthetic sessions.- Real-session validation (ESP32 capture + chest strap) remains a follow-up requiring hardware evidence per CLAUDE.md.